| | 09800HB2728ham001 | - 2 - | LRB098 08579 MGM 42999 a |
|
|
1 | | detector installed on the upper level shall suffice for the
|
2 | | adjacent lower level if the lower level is less than one full |
3 | | story below
the upper level; however, if there is an |
4 | | intervening door between the
adjacent levels, a smoke detector |
5 | | shall be installed on each level.
|
6 | | (c) Every structure which (1) contains more than one |
7 | | dwelling unit, or
(2) contains at least one dwelling unit and |
8 | | is a mixed-use structure, shall
contain at least one approved |
9 | | smoke detector at the uppermost ceiling of
each interior |
10 | | stairwell. The detector shall be installed on the ceiling,
at |
11 | | least 6 inches from the wall, or on a wall located between 4 |
12 | | and 6
inches from the ceiling.
|
13 | | (d) It shall be the responsibility of the owner of a |
14 | | structure to supply
and install all required detectors. The |
15 | | owner shall be responsible for
making reasonable efforts to |
16 | | test and maintain detectors in common
stairwells and hallways. |
17 | | It shall be the responsibility of a tenant to
test and to |
18 | | provide general maintenance for the detectors within the
|
19 | | tenant's dwelling unit or rooming unit, and to notify the owner |
20 | | or the
authorized agent of the owner in writing of any |
21 | | deficiencies which the
tenant cannot correct. The owner shall |
22 | | be responsible for providing one
tenant per dwelling unit with |
23 | | written information regarding detector
testing and |
24 | | maintenance.
|
25 | | The tenant shall be responsible for replacement of any |
26 | | required batteries
in the smoke detectors in the tenant's |
|
| | 09800HB2728ham001 | - 3 - | LRB098 08579 MGM 42999 a |
|
|
1 | | dwelling unit, except that the owner
shall ensure that such |
2 | | batteries are in operating condition at the time
the tenant |
3 | | takes possession of the dwelling unit. The tenant shall provide
|
4 | | the owner or the authorized agent of the owner with access to |
5 | | the dwelling
unit to correct any deficiencies in the smoke |
6 | | detector which have been
reported in writing to the owner or |
7 | | the authorized agent of the owner.
|
8 | | (e) The requirements of this Section shall apply to any |
9 | | dwelling unit
in existence on July 1, 1988, beginning on that |
10 | | date. Except as provided
in subsections (f) and (g), the smoke |
11 | | detectors required in such dwelling
units may be either battery |
12 | | powered or wired into the structure's AC power
line, and need |
13 | | not be interconnected.
|
14 | | (f) In the case of any dwelling unit that is newly |
15 | | constructed,
reconstructed, or substantially remodelled after |
16 | | December 31, 1987, the
requirements of this Section shall apply |
17 | | beginning on the first day of
occupancy of the dwelling unit |
18 | | after such construction, reconstruction or
substantial |
19 | | remodelling. The smoke detectors required in such dwelling
unit |
20 | | shall be permanently wired into the structure's AC power line, |
21 | | and if
more than one detector is required to be installed |
22 | | within the dwelling
unit, the detectors shall be wired so that |
23 | | the actuation of one detector
will actuate all the detectors in |
24 | | the dwelling unit.
|
25 | | In the case of any dwelling unit that is newly constructed,
|
26 | | reconstructed, or substantially remodeled on or after January |
|
| | 09800HB2728ham001 | - 4 - | LRB098 08579 MGM 42999 a |
|
|
1 | | 1, 2011, smoke detectors permanently wired into the structure's |
2 | | AC power line must also maintain an alternative back-up power |
3 | | source, which may be either a battery or batteries or an |
4 | | emergency generator. |
5 | | (g) Every hotel shall be equipped with operational portable
|
6 | | smoke-detecting alarm devices for the deaf and hearing impaired |
7 | | of audible
and visual design, available for units of occupancy.
|
8 | | Specialized smoke-detectors for the deaf and hearing |
9 | | impaired shall be
available upon request by guests in such |
10 | | hotels at a rate
of at least one such smoke detector per 75 |
11 | | occupancy units or portions
thereof, not to exceed 5 such smoke |
12 | | detectors per hotel.
Incorporation or connection into an |
13 | | existing interior alarm system, so as
to be capable of being |
14 | | activated by the system, may be utilized in lieu of
the |
15 | | portable alarms.
|
16 | | Operators of any hotel shall post conspicuously at the main |
17 | | desk a
permanent notice, in letters at least 3 inches in |
18 | | height, stating that
smoke detector alarm devices for the deaf |
19 | | and hearing impaired are
available. The proprietor may require |
20 | | a refundable deposit for a portable
smoke detector not to |
21 | | exceed the cost of the detector.
|
22 | | (g-5) A hotel, as defined in this Act, shall be responsible |
23 | | for installing and maintaining smoke detecting equipment. |
24 | | (h) Compliance with an applicable federal, State or local |
25 | | law or
building code which requires the installation and |
26 | | maintenance of smoke
detectors in a manner different from this |
|
| | 09800HB2728ham001 | - 5 - | LRB098 08579 MGM 42999 a |
|
|
1 | | Section, but providing a level of
safety for occupants which is |
2 | | equal to or greater than that provided by
this Section, shall |
3 | | be deemed to be in compliance with this Section, and
the |
4 | | requirements of such more stringent law shall govern over the
|
5 | | requirements of this Section.
|
6 | | (Source: P.A. 96-1292, eff. 1-1-11; 97-447, eff. 1-1-12.)".
|