| | SB2702 Engrossed | | LRB103 36180 RPS 66272 b |
|
|
1 | | AN ACT concerning regulation. |
2 | | Be it enacted by the People of the State of Illinois, |
3 | | represented in the General Assembly: |
4 | | Section 5. The Fire Sprinkler Contractor Licensing Act is |
5 | | amended by changing Sections 10 and 17 as follows: |
6 | | (225 ILCS 317/10) |
7 | | Sec. 10. Definitions. As used in this Act, unless the |
8 | | context otherwise requires: |
9 | | "Designated certified person" means an individual who has |
10 | | met the qualifications set forth under Section 20. |
11 | | "Fire protection system layout documents" means layout |
12 | | drawings, catalog information on standard products, and other |
13 | | construction data that provide detail on the location of |
14 | | risers, cross mains, branch lines, sprinklers, piping per |
15 | | applicable standard, and hanger locations. "Fire protection |
16 | | system layout documents" serve as a guide for fabrication and |
17 | | installation of a fire sprinkler system and shall be based |
18 | | upon applicable standards pursuant to Section 30. |
19 | | "Fire sprinkler contractor" means a person who holds |
20 | | himself or herself out to be in the business of providing |
21 | | service for a fire sprinkler system or contracts with a person |
22 | | to provide service for a fire sprinkler system. |
23 | | "Fire sprinkler contractor license" means a license issued |
|
| | SB2702 Engrossed | - 2 - | LRB103 36180 RPS 66272 b |
|
|
1 | | to a qualified fire sprinkler contractor. |
2 | | "Fire sprinkler inspector" means an individual who is |
3 | | qualified to perform routine inspection or testing of fire |
4 | | sprinkler systems pursuant to Section 17 and who is employed |
5 | | or contracted by a single fire sprinkler contractor at a time |
6 | | to perform fire sprinkler inspections . |
7 | | "Fire sprinkler inspector license" means a license issued |
8 | | to a qualified fire sprinkler inspector. |
9 | | "Fire sprinkler system" means any water-based automatic |
10 | | fire extinguishing system employing fire sprinklers, including |
11 | | accessory fire pumps and associated piping, fire standpipes, |
12 | | or underground fire main systems starting at the connection to |
13 | | the water service after the approved backflow device is |
14 | | installed under the requirements of the Illinois Plumbing Code |
15 | | and ending at the most remote fire sprinkler. "Fire sprinkler |
16 | | system" includes but is not limited to a fire sprinkler system |
17 | | in a residential, commercial, institutional, educational, |
18 | | public, or private occupancy. "Fire sprinkler system" does not |
19 | | include single sprinkler heads that are in a loop of the |
20 | | potable water system, as referenced in 77 Ill. Adm. Code |
21 | | 890.1130 and 890.1200. |
22 | | "Licensee" means a person or business organization |
23 | | licensed in accordance with this Act. |
24 | | "NICET" means the National Institute for Certification in |
25 | | Engineering Technologies. |
26 | | "Office" means the Office of the State Fire Marshal. |
|
| | SB2702 Engrossed | - 3 - | LRB103 36180 RPS 66272 b |
|
|
1 | | "Person" means an individual, group of individuals, |
2 | | association, trust, partnership, corporation, limited |
3 | | liability company, firm, business, person doing business under |
4 | | an assumed name, the State of Illinois, or department thereof, |
5 | | any other state-owned and operated institution, or any other |
6 | | entity. |
7 | | "Responsible managing employee" means the individual |
8 | | designated by the fire sprinkler contractor that is not |
9 | | required to have a designated certified person under Section |
10 | | 120. |
11 | | "Routine inspection or testing" means inspection or |
12 | | testing to verify the condition of an existing fire sprinkler |
13 | | system at predetermined intervals in accordance with the |
14 | | standards of the National Fire Protection Association. |
15 | | "Rules" means the rules adopted pursuant to this Act. |
16 | | "Service" means work on a fire sprinkler system, |
17 | | including, but not limited to, installation, repair, |
18 | | inspection, testing, and maintenance, within the scope of this |
19 | | Act. |
20 | | "Standards" means those standards or codes referenced in |
21 | | this Act or its rules. |
22 | | "Supervision" means the direction and management by a |
23 | | designated certified person or responsible managing employee |
24 | | of the activities of non-certified personnel in the service of |
25 | | fire sprinkler systems. |
26 | | (Source: P.A. 102-612, eff. 8-27-21.) |
|
| | SB2702 Engrossed | - 4 - | LRB103 36180 RPS 66272 b |
|
|
1 | | (225 ILCS 317/17) |
2 | | Sec. 17. Fire sprinkler inspector license; application; |
3 | | minimum qualifications for routine inspection or testing. |
4 | | (a) Any individual who performs routine inspection or |
5 | | testing of any fire sprinkler system under this Act shall: (i) |
6 | | be employed by a single licensed fire sprinkler contractor at |
7 | | a time to perform fire sprinkler inspections ; and (ii) meet |
8 | | the minimum qualifications of this Section except where the |
9 | | individual is exempted by subsection (c). |
10 | | Beginning January 1, 2024, any individual who performs |
11 | | routine inspection or testing of any fire sprinkler system |
12 | | under this Act shall be individually licensed and possess on |
13 | | his or her person a fire sprinkler inspector license including |
14 | | a photo identification issued by the Office. |
15 | | A person applying for an initial fire sprinkler inspector |
16 | | license or renewing a fire sprinkler inspector license shall |
17 | | demonstrate to the Office proof of minimum qualifications as |
18 | | required by subsection (b) of this Section, except where the |
19 | | individual is exempted by subsection (c). |
20 | | (b) Any individual who performs routine inspection or |
21 | | testing of any fire sprinkler system under this Act shall |
22 | | possess proof of: |
23 | | (1) current certification by a nationally recognized |
24 | | certification organization, such as NICET certification in |
25 | | Inspection and Testing of Water Based Systems, at an |
|
| | SB2702 Engrossed | - 5 - | LRB103 36180 RPS 66272 b |
|
|
1 | | appropriate level, or the equivalent; on or after the |
2 | | effective date of this amendatory Act of the 102nd General |
3 | | assembly through December 31, 2022, an appropriate level |
4 | | in NICET certification in Inspection and Testing of Water |
5 | | Based Systems shall be level II; on and after January 1, |
6 | | 2023, an appropriate level in NICET certification in |
7 | | Inspection and Testing of Water Based Systems shall be |
8 | | level III; |
9 | | (2) current ASSE 15010 certification in inspection, |
10 | | testing, and maintenance for water-based fire protection |
11 | | systems by the American Society of Sanitary Engineering; |
12 | | or |
13 | | (3) satisfactory completion of a certified sprinkler |
14 | | fitter apprenticeship program approved by the U.S. |
15 | | Department of Labor. |
16 | | (c) The following are exemptions to the licensing |
17 | | requirements of this Section: |
18 | | (1) State employees who perform routine inspection or |
19 | | testing on behalf of State institutions and who meet the |
20 | | requirements of subsection (b) need not be licensed under |
21 | | this Section or employed by a fire sprinkler contractor |
22 | | under this Act in order to perform routine inspection or |
23 | | testing duties while engaged in the performance of their |
24 | | official duties. |
25 | | (2) The requirements of this Section do not apply to |
26 | | individuals performing inspection or testing of fire |
|
| | SB2702 Engrossed | - 6 - | LRB103 36180 RPS 66272 b |
|
|
1 | | sprinkler systems on behalf of a municipality, a county, a |
2 | | fire department, a fire protection district, or the Office |
3 | | while engaged in the performance of their official duties. |
4 | | (3) The requirements of this Section do not apply to a |
5 | | stationary engineer, operating engineer, or other |
6 | | individual employed on a full-time basis by the facility |
7 | | owner or owner's representative performing weekly and |
8 | | monthly inspections and tests in accordance with |
9 | | applicable standards adopted under the rules. |
10 | | (d) Each fire sprinkler inspector shall be subject to the |
11 | | requirements for license renewal and continuing education |
12 | | under Section 35. |
13 | | (e) Nothing in this Act shall be construed to prohibit an |
14 | | individual who is licensed as a fire sprinkler inspector from |
15 | | being employed by another employer or self-employed to perform |
16 | | duties that would not require a fire sprinkler inspector |
17 | | license. |
18 | | (Source: P.A. 102-612, eff. 8-27-21.) |