1 | | emissions standards in 40 CFR 63.362. |
2 | | "Exhaust point" means any point through which ethylene |
3 | | oxide-laden air exits an ethylene oxide sterilization source. |
4 | | "Stationary source" has the meaning set forth in subsection |
5 | | 1 of Section 39.5. |
6 | | (b) Beginning 180 days after the effective date of this |
7 | | amendatory Act of the 101st General Assembly, no person shall |
8 | | conduct ethylene oxide sterilization operations, unless the |
9 | | ethylene oxide sterilization source captures, and demonstrates |
10 | | that it captures, 100% of all ethylene oxide emissions and |
11 | | reduces ethylene oxide emissions to the atmosphere from each |
12 | | exhaust point at the ethylene oxide sterilization source by at |
13 | | least 99.9% or to 0.2 parts per million. |
14 | | (1) Within 180 days after the effective date of this |
15 | | amendatory Act of the 101st General Assembly for any |
16 | | existing ethylene oxide sterilization source or prior to |
17 | | any ethylene oxide sterilization operation for any source |
18 | | that first becomes subject to regulation after the |
19 | | effective date of this amendatory Act of the 101st General |
20 | | Assembly as an ethylene oxide sterilization source under |
21 | | this Section, the owner or operator of the ethylene oxide |
22 | | sterilization source shall conduct an initial emissions |
23 | | test in accordance with all of the requirements set forth |
24 | | in this paragraph (1) to verify that ethylene oxide |
25 | | emissions to the atmosphere from each exhaust point at the |
26 | | ethylene oxide sterilization source have been reduced by at |
|
| | 10100HB0457ham004 | - 3 - | LRB101 03567 AMC 59682 a |
|
|
1 | | least 99.9% or to 0.2 parts per million: |
2 | | (A) At least 30 days prior to the scheduled |
3 | | emissions test date, the owner or operator of the |
4 | | ethylene oxide sterilization source shall submit a |
5 | | notification of the scheduled emissions test date and a |
6 | | copy of the proposed emissions test protocol to the |
7 | | Agency for review and written approval. Emissions test |
8 | | protocols submitted to the Agency shall address the |
9 | | manner in which testing will be conducted, including, |
10 | | but not limited to: |
11 | | (i) the person or persons who will be |
12 | | performing sampling and analysis and their |
13 | | experience with similar emissions tests; |
14 | | (ii) the methodologies to be used; |
15 | | (iii) the conditions under which emissions |
16 | | tests will be performed, including a discussion of |
17 | | why these conditions will be representative of |
18 | | maximum emissions from each of the 3 cycles of |
19 | | operation (chamber evacuation, back vent, and |
20 | | aeration) and the means by which the operating |
21 | | parameters for the emission unit and any control |
22 | | equipment will be determined; |
23 | | (iv) the specific determinations of emissions |
24 | | and operations that are intended to be made, |
25 | | including sampling and monitoring locations; and |
26 | | (v) any changes to the test method or methods |
|
| | 10100HB0457ham004 | - 4 - | LRB101 03567 AMC 59682 a |
|
|
1 | | proposed to accommodate the specific circumstances |
2 | | of testing, with justification. |
3 | | (B) The owner or operator of the ethylene oxide |
4 | | sterilization source shall perform emissions testing |
5 | | in accordance with an Agency-approved test protocol |
6 | | and at representative conditions to verify that |
7 | | ethylene oxide emissions to the atmosphere from each |
8 | | exhaust point at the ethylene oxide sterilization |
9 | | source have been reduced by at least 99.9% or to 0.2 |
10 | | parts per million. The duration of the test must |
11 | | incorporate all 3 cycles of operation for |
12 | | determination of the emission reduction efficiency. |
13 | | (C) Upon Agency approval of the test protocol, any |
14 | | source that first becomes subject to regulation after |
15 | | the effective date of this amendatory Act of the 101st |
16 | | General Assembly as an ethylene oxide sterilization |
17 | | source under this Section may undertake ethylene oxide |
18 | | sterilization operations in accordance with the |
19 | | Agency-approved test protocol for the sole purpose of |
20 | | demonstrating compliance with this subsection (b). |
21 | | (D) The owner or operator of the ethylene oxide |
22 | | sterilization source shall submit to the Agency the |
23 | | results of any and all emissions testing conducted |
24 | | after the effective date of this amendatory Act of the |
25 | | 101st General Assembly, until such time as the Agency |
26 | | accepts testing results under subparagraph (E) of |
|
| | 10100HB0457ham004 | - 5 - | LRB101 03567 AMC 59682 a |
|
|
1 | | paragraph (1) of this subsection (b), for any existing |
2 | | source or prior to any ethylene oxide sterilization |
3 | | operation for any source that first becomes subject to |
4 | | regulation after the effective date of this amendatory |
5 | | Act of the 101st General Assembly as an ethylene oxide |
6 | | sterilization source under this Section. The results |
7 | | documentation shall include at a minimum: |
8 | | (i) a summary of results; |
9 | | (ii) a description of test method or methods, |
10 | | including description of sample points, sampling |
11 | | train, analysis equipment, and test schedule; |
12 | | (iii) a detailed description of test |
13 | | conditions, including process information and |
14 | | control equipment information; and |
15 | | (iv) data and calculations, including copies |
16 | | of all raw data sheets, opacity observation |
17 | | records and records of laboratory analyses, sample |
18 | | calculations, and equipment calibration. |
19 | | (E) The Agency shall accept, accept with |
20 | | conditions, or decline to accept testing results |
21 | | submitted to demonstrate compliance with paragraph (1) |
22 | | of this subsection (b). If the Agency accepts with |
23 | | conditions or declines to accept the results |
24 | | submitted, the owner or operator of the ethylene oxide |
25 | | sterilization source shall submit revised results of |
26 | | the emissions testing or conduct emissions testing |
|
| | 10100HB0457ham004 | - 6 - | LRB101 03567 AMC 59682 a |
|
|
1 | | again. If the owner or operator revises the results, |
2 | | the revised results shall be submitted within 15 days |
3 | | after the owner or operator of the ethylene oxide |
4 | | sterilization source receives written notice of the |
5 | | Agency's conditional acceptance or rejection of the |
6 | | emissions testing results. If the owner or operator |
7 | | conducts emissions testing again, such new emissions |
8 | | testing shall conform to the requirements of this |
9 | | subsection (b). |
10 | | (2) The owner or operator of the ethylene oxide |
11 | | sterilization source shall conduct emissions testing on |
12 | | all exhaust points at the ethylene oxide sterilization |
13 | | source at least once each calendar year to demonstrate |
14 | | compliance with the requirements of this Section and any |
15 | | applicable requirements concerning ethylene oxide that are |
16 | | set forth in either United States Environmental Protection |
17 | | Agency rules or Board rules. Annual emissions tests |
18 | | required under this paragraph (2) shall take place at least |
19 | | 6 months apart. An initial emissions test conducted under |
20 | | paragraph (1) of this subsection (b) satisfies the testing |
21 | | requirement of this paragraph (2) for the calendar year in |
22 | | which the initial emissions test is conducted. |
23 | | (3) At least 30 days before conducting the annual |
24 | | emissions test required under paragraph (2) of this |
25 | | subsection (b), the owner or operator shall submit a |
26 | | notification of the scheduled emissions test date and a |
|
| | 10100HB0457ham004 | - 7 - | LRB101 03567 AMC 59682 a |
|
|
1 | | copy of the proposed emissions test protocol to the Agency |
2 | | for review and written approval. Emissions test protocols |
3 | | submitted to the Agency under this paragraph (3) must |
4 | | address each item listed in subparagraph (A) of paragraph |
5 | | (1) of this subsection (b). Emissions testing shall be |
6 | | performed in accordance with an Agency-approved test |
7 | | protocol and at representative conditions. In addition, |
8 | | within 30 days after the emissions test date, the owner or |
9 | | operator shall submit to the Agency the results of the |
10 | | emissions testing required under paragraph (2) of this |
11 | | subsection (b). Such results must include each item listed |
12 | | in subparagraph (D) of paragraph (1) of this subsection |
13 | | (b). |
14 | | (4) If the owner or operator of an ethylene oxide |
15 | | sterilization source conducts any emissions testing in |
16 | | addition to tests required by this amendatory Act of the |
17 | | 101st General Assembly, the owner or operator shall submit |
18 | | to the Agency the results of such emissions testing within |
19 | | 30 days after the emissions test date. |
20 | | (5) The Agency shall accept, accept with conditions, or |
21 | | decline to accept testing results submitted to demonstrate |
22 | | compliance with paragraph (2) of this subsection (b). If |
23 | | the Agency accepts with conditions or declines to accept |
24 | | the results submitted, the owner or operator of the |
25 | | ethylene oxide sterilization source shall submit revised |
26 | | results of the emissions testing or conduct emissions |
|
| | 10100HB0457ham004 | - 8 - | LRB101 03567 AMC 59682 a |
|
|
1 | | testing again. If the owner or operator revises the |
2 | | results, the revised results shall be submitted within 15 |
3 | | days after the owner or operator of the ethylene oxide |
4 | | sterilization source receives written notice of the |
5 | | Agency's conditional acceptance or rejection of the |
6 | | emissions testing results. If the owner or operator |
7 | | conducts emissions testing again, such new emissions |
8 | | testing shall conform to the requirements of this |
9 | | subsection (b). |
10 | | (c) If any emissions test conducted more than 180 days |
11 | | after the effective date of this amendatory Act of the 101st |
12 | | General Assembly fails to demonstrate that ethylene oxide |
13 | | emissions to the atmosphere from each exhaust point at the |
14 | | ethylene oxide sterilization source have been reduced by at |
15 | | least 99.9% or to 0.2 parts per million, the owner or operator |
16 | | of the ethylene oxide sterilization source shall immediately |
17 | | cease ethylene oxide sterilization operations and notify the |
18 | | Agency within 24 hours of becoming aware of the failed |
19 | | emissions test. Within 60 days after the date of the test, the |
20 | | owner or operator of the ethylene oxide sterilization source |
21 | | shall: |
22 | | (1) complete an analysis to determine the root cause of |
23 | | the failed emissions test; |
24 | | (2) take any actions necessary to address that root |
25 | | cause; |
26 | | (3) submit a report to the Agency describing the |
|
| | 10100HB0457ham004 | - 9 - | LRB101 03567 AMC 59682 a |
|
|
1 | | findings of the root cause analysis, any work undertaken to |
2 | | address findings of the root cause analysis, and |
3 | | identifying any feasible best management practices to |
4 | | enhance capture and further reduce ethylene oxide levels |
5 | | within the ethylene oxide sterilization source, including |
6 | | a schedule for implementing such practices; and |
7 | | (4) upon approval by the Agency of the report required |
8 | | by paragraph (3) of this subsection, restart ethylene oxide |
9 | | sterilization operations only to the extent necessary to |
10 | | conduct additional emissions test or tests. The ethylene |
11 | | oxide sterilization source shall conduct such emissions |
12 | | test or tests under the same requirements as the annual |
13 | | test described in paragraphs (2) and (3) of subsection (b). |
14 | | The ethylene oxide sterilization source may restart |
15 | | operations once an emissions test successfully |
16 | | demonstrates that ethylene oxide emissions to the |
17 | | atmosphere from each exhaust point at the ethylene oxide |
18 | | sterilization source have been reduced by at least 99.9% or |
19 | | to 0.2 parts per million, the source has submitted the |
20 | | results of all emissions testing conducted under this |
21 | | subsection to the Agency, and the Agency has approved the |
22 | | results demonstrating compliance. |
23 | | (d) Beginning 180 days after the effective date of this |
24 | | amendatory Act of the 101st General Assembly for any existing |
25 | | source or prior to any ethylene oxide sterilization operation |
26 | | for any source that first becomes subject to regulation after |
|
| | 10100HB0457ham004 | - 10 - | LRB101 03567 AMC 59682 a |
|
|
1 | | the effective date of this amendatory Act of the 101st General |
2 | | Assembly as an ethylene oxide sterilization source under this |
3 | | Section, no person shall conduct ethylene oxide sterilization |
4 | | operations unless the owner or operator of the ethylene oxide |
5 | | sterilization source submits for review and approval by the |
6 | | Agency a plan describing how the owner or operator will |
7 | | continuously collect emissions information at the ethylene |
8 | | oxide sterilization source. This plan must also specify |
9 | | locations at the ethylene oxide sterilization source from which |
10 | | emissions will be collected and identify equipment used for |
11 | | collection and analysis, including the individual system |
12 | | components. |
13 | | (1) The owner or operator of the ethylene oxide |
14 | | sterilization source must provide a notice of acceptance of |
15 | | any conditions added by the Agency to the plan, or correct |
16 | | any deficiencies identified by the Agency in the plan, |
17 | | within 3 business days after receiving the Agency's |
18 | | conditional acceptance or denial of the plan. |
19 | | (2) Upon the Agency's approval of the plan, the owner |
20 | | or operator of the ethylene oxide sterilization source |
21 | | shall implement the plan in accordance with its approved |
22 | | terms. |
23 | | (e) Beginning 180 days after the effective date of this |
24 | | amendatory Act of the 101st General Assembly for any existing |
25 | | source or prior to any ethylene oxide sterilization operation |
26 | | for any source that first becomes subject to regulation after |
|
| | 10100HB0457ham004 | - 11 - | LRB101 03567 AMC 59682 a |
|
|
1 | | the effective date of this amendatory Act of the 101st General |
2 | | Assembly as an ethylene oxide sterilization source under this |
3 | | Section, no person shall conduct ethylene oxide sterilization |
4 | | operations unless the owner or operator of the ethylene oxide |
5 | | sterilization source submits for review and approval by the |
6 | | Agency an Ambient Air Monitoring Plan. The Ambient Air |
7 | | Monitoring Plan shall include, at a minimum, detailed plans to |
8 | | collect and analyze air samples for ethylene oxide on at least |
9 | | a quarterly basis near the property boundaries of the ethylene |
10 | | oxide sterilization source and at community locations with the |
11 | | highest modeled impact pursuant to the modeling conducted under |
12 | | subsection (f) and a schedule for implementation. |
13 | | (1) The owner or operator of the ethylene oxide |
14 | | sterilization source must provide a notice of acceptance of |
15 | | any conditions added by the Agency to the Ambient Air |
16 | | Monitoring Plan, or correct any deficiencies identified by |
17 | | the Agency in the Ambient Air Monitoring Plan, within 3 |
18 | | business days after receiving the Agency's conditional |
19 | | acceptance or denial of the plan. |
20 | | (2) Upon the Agency's approval of the plan, the owner |
21 | | or operator of the ethylene oxide sterilization source |
22 | | shall implement the Ambient Air Monitoring Plan in |
23 | | accordance with its approved terms. |
24 | | (f) Beginning 180 days after the effective date of this |
25 | | amendatory Act of the 101st General Assembly for any existing |
26 | | source or prior to any ethylene oxide sterilization operation |
|
| | 10100HB0457ham004 | - 12 - | LRB101 03567 AMC 59682 a |
|
|
1 | | for any source that first becomes subject to regulation after |
2 | | the effective date of this amendatory Act of the 101st General |
3 | | Assembly as an ethylene oxide sterilization source under this |
4 | | Section, no person shall conduct ethylene oxide sterilization |
5 | | operations unless the owner or operator of the ethylene oxide |
6 | | sterilization source has performed dispersion modeling and the |
7 | | Agency approves such modeling. |
8 | | (1) Dispersion modeling must: |
9 | | (A) be conducted using accepted United States |
10 | | Environmental Protection Agency methodologies, |
11 | | including 40 CFR Part 51, Appendix W, except that no |
12 | | background ambient levels of ethylene oxide shall be |
13 | | used; |
14 | | (B) use emissions and stack parameter data from the |
15 | | emissions test conducted in accordance with paragraph |
16 | | (1) of subsection (b), and use 5 years of hourly |
17 | | meteorological data that is representative of the |
18 | | source's location; and |
19 | | (C) use a receptor grid that extends to at least |
20 | | one kilometer around the source and ensure the modeling |
21 | | domain includes the area of maximum impact, with |
22 | | receptor spacing no greater than every 50 meters |
23 | | starting from the building walls of the source |
24 | | extending out to a distance of at least one-half |
25 | | kilometer, then every 100 meters extending out to a |
26 | | distance of at least one kilometer. |
|
| | 10100HB0457ham004 | - 13 - | LRB101 03567 AMC 59682 a |
|
|
1 | | (2) The owner or operator of the ethylene oxide |
2 | | sterilization source shall submit revised results of all |
3 | | modeling if the Agency accepts with conditions or declines |
4 | | to accept the results submitted. |
5 | | (g) The owner or operator of an ethylene oxide |
6 | | sterilization source must apply for and obtain a construction |
7 | | permit from the Agency for any modifications made to the source |
8 | | to comply with the requirements of this amendatory Act of the |
9 | | 101st General Assembly, including, but not limited to, |
10 | | installation of a permanent total enclosure, modification of |
11 | | airflow to create negative pressure within the source, and |
12 | | addition of one or more control devices. Additionally, the |
13 | | owner or operator of the ethylene oxide sterilization source |
14 | | must apply for and obtain from the Agency a modification of the |
15 | | source's operating permit to incorporate such modifications |
16 | | made to the source. Both the construction permit and operating |
17 | | permit must include a limit on ethylene oxide usage at the |
18 | | source. |
19 | | (h) The owner or operator of an ethylene oxide |
20 | | sterilization source must notify the Agency within 5 days after |
21 | | discovering any deviation from any of the requirements in this |
22 | | Section or deviations from any applicable requirements |
23 | | concerning ethylene oxide that are set forth in this Act, |
24 | | United States Environmental Protection Agency rules, or Board |
25 | | rules. Within 30 days after the Agency receives such |
26 | | notification, the Agency must post a notice on its website and |
|
| | 10100HB0457ham004 | - 14 - | LRB101 03567 AMC 59682 a |
|
|
1 | | notify the members of the General Assembly from the Legislative |
2 | | and Representative Districts in which the source in question is |
3 | | located, the county board members of the county in which the |
4 | | source in question is located, the corporate authorities of the |
5 | | municipality in which the source in question is located, and |
6 | | the Illinois Department of Public Health. |
7 | | (i) The Agency must conduct at least one unannounced |
8 | | inspection of all ethylene oxide sterilization sources subject |
9 | | to this Section per year. Nothing in this Section shall limit |
10 | | the Agency's authority under other provisions of this Act to |
11 | | conduct inspections of ethylene oxide sterilization sources.
|
12 | | Section 99. Effective date. This Act takes effect upon |
13 | | becoming law.".
|