Rep. Sam Yingling

Filed: 4/11/2019

 

 


 

 


 
10100HB0457ham004LRB101 03567 AMC 59682 a

1
AMENDMENT TO HOUSE BILL 457

2    AMENDMENT NO. ______. Amend House Bill 457 by replacing
3everything after the enacting clause with the following:
 
4    "Section 5. The Environmental Protection Act is amended by
5adding Section 9.16 as follows:
 
6    (415 ILCS 5/9.16 new)
7    Sec. 9.16. Control of ethylene oxide sterilization
8sources.
9    (a) As used in this Section:
10    "Ethylene oxide sterilization operations" means the
11process of using ethylene oxide at an ethylene oxide
12sterilization source to make one or more items free from
13microorganisms, pathogens, or both microorganisms and
14pathogens.
15    "Ethylene oxide sterilization source" means any stationary
16source with ethylene oxide usage that would subject it to the

 

 

10100HB0457ham004- 2 -LRB101 03567 AMC 59682 a

1emissions standards in 40 CFR 63.362.
2    "Exhaust point" means any point through which ethylene
3oxide-laden air exits an ethylene oxide sterilization source.
4    "Stationary source" has the meaning set forth in subsection
51 of Section 39.5.
6    (b) Beginning 180 days after the effective date of this
7amendatory Act of the 101st General Assembly, no person shall
8conduct ethylene oxide sterilization operations, unless the
9ethylene oxide sterilization source captures, and demonstrates
10that it captures, 100% of all ethylene oxide emissions and
11reduces ethylene oxide emissions to the atmosphere from each
12exhaust point at the ethylene oxide sterilization source by at
13least 99.9% or to 0.2 parts per million.
14        (1) Within 180 days after the effective date of this
15    amendatory Act of the 101st General Assembly for any
16    existing ethylene oxide sterilization source or prior to
17    any ethylene oxide sterilization operation for any source
18    that first becomes subject to regulation after the
19    effective date of this amendatory Act of the 101st General
20    Assembly as an ethylene oxide sterilization source under
21    this Section, the owner or operator of the ethylene oxide
22    sterilization source shall conduct an initial emissions
23    test in accordance with all of the requirements set forth
24    in this paragraph (1) to verify that ethylene oxide
25    emissions to the atmosphere from each exhaust point at the
26    ethylene oxide sterilization source have been reduced by at

 

 

10100HB0457ham004- 3 -LRB101 03567 AMC 59682 a

1    least 99.9% or to 0.2 parts per million:
2            (A) At least 30 days prior to the scheduled
3        emissions test date, the owner or operator of the
4        ethylene oxide sterilization source shall submit a
5        notification of the scheduled emissions test date and a
6        copy of the proposed emissions test protocol to the
7        Agency for review and written approval. Emissions test
8        protocols submitted to the Agency shall address the
9        manner in which testing will be conducted, including,
10        but not limited to:
11                (i) the person or persons who will be
12            performing sampling and analysis and their
13            experience with similar emissions tests;
14                (ii) the methodologies to be used;
15                (iii) the conditions under which emissions
16            tests will be performed, including a discussion of
17            why these conditions will be representative of
18            maximum emissions from each of the 3 cycles of
19            operation (chamber evacuation, back vent, and
20            aeration) and the means by which the operating
21            parameters for the emission unit and any control
22            equipment will be determined;
23                (iv) the specific determinations of emissions
24            and operations that are intended to be made,
25            including sampling and monitoring locations; and
26                (v) any changes to the test method or methods

 

 

10100HB0457ham004- 4 -LRB101 03567 AMC 59682 a

1            proposed to accommodate the specific circumstances
2            of testing, with justification.
3            (B) The owner or operator of the ethylene oxide
4        sterilization source shall perform emissions testing
5        in accordance with an Agency-approved test protocol
6        and at representative conditions to verify that
7        ethylene oxide emissions to the atmosphere from each
8        exhaust point at the ethylene oxide sterilization
9        source have been reduced by at least 99.9% or to 0.2
10        parts per million. The duration of the test must
11        incorporate all 3 cycles of operation for
12        determination of the emission reduction efficiency.
13            (C) Upon Agency approval of the test protocol, any
14        source that first becomes subject to regulation after
15        the effective date of this amendatory Act of the 101st
16        General Assembly as an ethylene oxide sterilization
17        source under this Section may undertake ethylene oxide
18        sterilization operations in accordance with the
19        Agency-approved test protocol for the sole purpose of
20        demonstrating compliance with this subsection (b).
21            (D) The owner or operator of the ethylene oxide
22        sterilization source shall submit to the Agency the
23        results of any and all emissions testing conducted
24        after the effective date of this amendatory Act of the
25        101st General Assembly, until such time as the Agency
26        accepts testing results under subparagraph (E) of

 

 

10100HB0457ham004- 5 -LRB101 03567 AMC 59682 a

1        paragraph (1) of this subsection (b), for any existing
2        source or prior to any ethylene oxide sterilization
3        operation for any source that first becomes subject to
4        regulation after the effective date of this amendatory
5        Act of the 101st General Assembly as an ethylene oxide
6        sterilization source under this Section. The results
7        documentation shall include at a minimum:
8                (i) a summary of results;
9                (ii) a description of test method or methods,
10            including description of sample points, sampling
11            train, analysis equipment, and test schedule;
12                (iii) a detailed description of test
13            conditions, including process information and
14            control equipment information; and
15                (iv) data and calculations, including copies
16            of all raw data sheets, opacity observation
17            records and records of laboratory analyses, sample
18            calculations, and equipment calibration.
19            (E) The Agency shall accept, accept with
20        conditions, or decline to accept testing results
21        submitted to demonstrate compliance with paragraph (1)
22        of this subsection (b). If the Agency accepts with
23        conditions or declines to accept the results
24        submitted, the owner or operator of the ethylene oxide
25        sterilization source shall submit revised results of
26        the emissions testing or conduct emissions testing

 

 

10100HB0457ham004- 6 -LRB101 03567 AMC 59682 a

1        again. If the owner or operator revises the results,
2        the revised results shall be submitted within 15 days
3        after the owner or operator of the ethylene oxide
4        sterilization source receives written notice of the
5        Agency's conditional acceptance or rejection of the
6        emissions testing results. If the owner or operator
7        conducts emissions testing again, such new emissions
8        testing shall conform to the requirements of this
9        subsection (b).
10        (2) The owner or operator of the ethylene oxide
11    sterilization source shall conduct emissions testing on
12    all exhaust points at the ethylene oxide sterilization
13    source at least once each calendar year to demonstrate
14    compliance with the requirements of this Section and any
15    applicable requirements concerning ethylene oxide that are
16    set forth in either United States Environmental Protection
17    Agency rules or Board rules. Annual emissions tests
18    required under this paragraph (2) shall take place at least
19    6 months apart. An initial emissions test conducted under
20    paragraph (1) of this subsection (b) satisfies the testing
21    requirement of this paragraph (2) for the calendar year in
22    which the initial emissions test is conducted.
23        (3) At least 30 days before conducting the annual
24    emissions test required under paragraph (2) of this
25    subsection (b), the owner or operator shall submit a
26    notification of the scheduled emissions test date and a

 

 

10100HB0457ham004- 7 -LRB101 03567 AMC 59682 a

1    copy of the proposed emissions test protocol to the Agency
2    for review and written approval. Emissions test protocols
3    submitted to the Agency under this paragraph (3) must
4    address each item listed in subparagraph (A) of paragraph
5    (1) of this subsection (b). Emissions testing shall be
6    performed in accordance with an Agency-approved test
7    protocol and at representative conditions. In addition,
8    within 30 days after the emissions test date, the owner or
9    operator shall submit to the Agency the results of the
10    emissions testing required under paragraph (2) of this
11    subsection (b). Such results must include each item listed
12    in subparagraph (D) of paragraph (1) of this subsection
13    (b).
14        (4) If the owner or operator of an ethylene oxide
15    sterilization source conducts any emissions testing in
16    addition to tests required by this amendatory Act of the
17    101st General Assembly, the owner or operator shall submit
18    to the Agency the results of such emissions testing within
19    30 days after the emissions test date.
20        (5) The Agency shall accept, accept with conditions, or
21    decline to accept testing results submitted to demonstrate
22    compliance with paragraph (2) of this subsection (b). If
23    the Agency accepts with conditions or declines to accept
24    the results submitted, the owner or operator of the
25    ethylene oxide sterilization source shall submit revised
26    results of the emissions testing or conduct emissions

 

 

10100HB0457ham004- 8 -LRB101 03567 AMC 59682 a

1    testing again. If the owner or operator revises the
2    results, the revised results shall be submitted within 15
3    days after the owner or operator of the ethylene oxide
4    sterilization source receives written notice of the
5    Agency's conditional acceptance or rejection of the
6    emissions testing results. If the owner or operator
7    conducts emissions testing again, such new emissions
8    testing shall conform to the requirements of this
9    subsection (b).
10    (c) If any emissions test conducted more than 180 days
11after the effective date of this amendatory Act of the 101st
12General Assembly fails to demonstrate that ethylene oxide
13emissions to the atmosphere from each exhaust point at the
14ethylene oxide sterilization source have been reduced by at
15least 99.9% or to 0.2 parts per million, the owner or operator
16of the ethylene oxide sterilization source shall immediately
17cease ethylene oxide sterilization operations and notify the
18Agency within 24 hours of becoming aware of the failed
19emissions test. Within 60 days after the date of the test, the
20owner or operator of the ethylene oxide sterilization source
21shall:
22        (1) complete an analysis to determine the root cause of
23    the failed emissions test;
24        (2) take any actions necessary to address that root
25    cause;
26        (3) submit a report to the Agency describing the

 

 

10100HB0457ham004- 9 -LRB101 03567 AMC 59682 a

1    findings of the root cause analysis, any work undertaken to
2    address findings of the root cause analysis, and
3    identifying any feasible best management practices to
4    enhance capture and further reduce ethylene oxide levels
5    within the ethylene oxide sterilization source, including
6    a schedule for implementing such practices; and
7        (4) upon approval by the Agency of the report required
8    by paragraph (3) of this subsection, restart ethylene oxide
9    sterilization operations only to the extent necessary to
10    conduct additional emissions test or tests. The ethylene
11    oxide sterilization source shall conduct such emissions
12    test or tests under the same requirements as the annual
13    test described in paragraphs (2) and (3) of subsection (b).
14    The ethylene oxide sterilization source may restart
15    operations once an emissions test successfully
16    demonstrates that ethylene oxide emissions to the
17    atmosphere from each exhaust point at the ethylene oxide
18    sterilization source have been reduced by at least 99.9% or
19    to 0.2 parts per million, the source has submitted the
20    results of all emissions testing conducted under this
21    subsection to the Agency, and the Agency has approved the
22    results demonstrating compliance.
23    (d) Beginning 180 days after the effective date of this
24amendatory Act of the 101st General Assembly for any existing
25source or prior to any ethylene oxide sterilization operation
26for any source that first becomes subject to regulation after

 

 

10100HB0457ham004- 10 -LRB101 03567 AMC 59682 a

1the effective date of this amendatory Act of the 101st General
2Assembly as an ethylene oxide sterilization source under this
3Section, no person shall conduct ethylene oxide sterilization
4operations unless the owner or operator of the ethylene oxide
5sterilization source submits for review and approval by the
6Agency a plan describing how the owner or operator will
7continuously collect emissions information at the ethylene
8oxide sterilization source. This plan must also specify
9locations at the ethylene oxide sterilization source from which
10emissions will be collected and identify equipment used for
11collection and analysis, including the individual system
12components.
13        (1) The owner or operator of the ethylene oxide
14    sterilization source must provide a notice of acceptance of
15    any conditions added by the Agency to the plan, or correct
16    any deficiencies identified by the Agency in the plan,
17    within 3 business days after receiving the Agency's
18    conditional acceptance or denial of the plan.
19        (2) Upon the Agency's approval of the plan, the owner
20    or operator of the ethylene oxide sterilization source
21    shall implement the plan in accordance with its approved
22    terms.
23    (e) Beginning 180 days after the effective date of this
24amendatory Act of the 101st General Assembly for any existing
25source or prior to any ethylene oxide sterilization operation
26for any source that first becomes subject to regulation after

 

 

10100HB0457ham004- 11 -LRB101 03567 AMC 59682 a

1the effective date of this amendatory Act of the 101st General
2Assembly as an ethylene oxide sterilization source under this
3Section, no person shall conduct ethylene oxide sterilization
4operations unless the owner or operator of the ethylene oxide
5sterilization source submits for review and approval by the
6Agency an Ambient Air Monitoring Plan. The Ambient Air
7Monitoring Plan shall include, at a minimum, detailed plans to
8collect and analyze air samples for ethylene oxide on at least
9a quarterly basis near the property boundaries of the ethylene
10oxide sterilization source and at community locations with the
11highest modeled impact pursuant to the modeling conducted under
12subsection (f) and a schedule for implementation.
13        (1) The owner or operator of the ethylene oxide
14    sterilization source must provide a notice of acceptance of
15    any conditions added by the Agency to the Ambient Air
16    Monitoring Plan, or correct any deficiencies identified by
17    the Agency in the Ambient Air Monitoring Plan, within 3
18    business days after receiving the Agency's conditional
19    acceptance or denial of the plan.
20        (2) Upon the Agency's approval of the plan, the owner
21    or operator of the ethylene oxide sterilization source
22    shall implement the Ambient Air Monitoring Plan in
23    accordance with its approved terms.
24    (f) Beginning 180 days after the effective date of this
25amendatory Act of the 101st General Assembly for any existing
26source or prior to any ethylene oxide sterilization operation

 

 

10100HB0457ham004- 12 -LRB101 03567 AMC 59682 a

1for any source that first becomes subject to regulation after
2the effective date of this amendatory Act of the 101st General
3Assembly as an ethylene oxide sterilization source under this
4Section, no person shall conduct ethylene oxide sterilization
5operations unless the owner or operator of the ethylene oxide
6sterilization source has performed dispersion modeling and the
7Agency approves such modeling.
8        (1) Dispersion modeling must:
9            (A) be conducted using accepted United States
10        Environmental Protection Agency methodologies,
11        including 40 CFR Part 51, Appendix W, except that no
12        background ambient levels of ethylene oxide shall be
13        used;
14            (B) use emissions and stack parameter data from the
15        emissions test conducted in accordance with paragraph
16        (1) of subsection (b), and use 5 years of hourly
17        meteorological data that is representative of the
18        source's location; and
19            (C) use a receptor grid that extends to at least
20        one kilometer around the source and ensure the modeling
21        domain includes the area of maximum impact, with
22        receptor spacing no greater than every 50 meters
23        starting from the building walls of the source
24        extending out to a distance of at least one-half
25        kilometer, then every 100 meters extending out to a
26        distance of at least one kilometer.

 

 

10100HB0457ham004- 13 -LRB101 03567 AMC 59682 a

1        (2) The owner or operator of the ethylene oxide
2    sterilization source shall submit revised results of all
3    modeling if the Agency accepts with conditions or declines
4    to accept the results submitted.
5    (g) The owner or operator of an ethylene oxide
6sterilization source must apply for and obtain a construction
7permit from the Agency for any modifications made to the source
8to comply with the requirements of this amendatory Act of the
9101st General Assembly, including, but not limited to,
10installation of a permanent total enclosure, modification of
11airflow to create negative pressure within the source, and
12addition of one or more control devices. Additionally, the
13owner or operator of the ethylene oxide sterilization source
14must apply for and obtain from the Agency a modification of the
15source's operating permit to incorporate such modifications
16made to the source. Both the construction permit and operating
17permit must include a limit on ethylene oxide usage at the
18source.
19    (h) The owner or operator of an ethylene oxide
20sterilization source must notify the Agency within 5 days after
21discovering any deviation from any of the requirements in this
22Section or deviations from any applicable requirements
23concerning ethylene oxide that are set forth in this Act,
24United States Environmental Protection Agency rules, or Board
25rules. Within 30 days after the Agency receives such
26notification, the Agency must post a notice on its website and

 

 

10100HB0457ham004- 14 -LRB101 03567 AMC 59682 a

1notify the members of the General Assembly from the Legislative
2and Representative Districts in which the source in question is
3located, the county board members of the county in which the
4source in question is located, the corporate authorities of the
5municipality in which the source in question is located, and
6the Illinois Department of Public Health.
7    (i) The Agency must conduct at least one unannounced
8inspection of all ethylene oxide sterilization sources subject
9to this Section per year. Nothing in this Section shall limit
10the Agency's authority under other provisions of this Act to
11conduct inspections of ethylene oxide sterilization sources.
 
12    Section 99. Effective date. This Act takes effect upon