TITLE 83: PUBLIC UTILITIES
CHAPTER I: ILLINOIS COMMERCE COMMISSION SUBCHAPTER d: GAS UTILITIES PART 501 STANDARDS OF SERVICE FOR GAS UTILITIES AND ALTERNATIVE GAS SUPPLIERS SECTION 501.300 CORRECTORS
Section 501.300 Correctors
a) A utility shall install all correctors in accordance with the recommendations of AGA Gas Measurement Manual, Electronic Corrector, Part No. 15 (May 1999), XQ9901.
b) A utility that installs an electronic or mechanical corrector shall verify the proper operation of the corrector at least every 60 months.
1) Verification temperatures are 32°F and 75°F/or flowing gas temperature with a tolerance of ± 2.5°F.
2) Verification pressures are zero and flowing pressure with a tolerance of ± 1%.
c) A utility shall maintain the most recent 10 years of inspection records. |