TITLE 35: ENVIRONMENTAL PROTECTION
SUBTITLE G: WASTE DISPOSAL CHAPTER I: POLLUTION CONTROL BOARD SUBCHAPTER f: RISK BASED CLEANUP OBJECTIVES PART 742 TIERED APPROACH TO CORRECTIVE ACTION OBJECTIVES SECTION 742.1205 BUILDING CONTROL TECHNOLOGY PROPOSALS
Section 742.1205 Building Control Technology Proposals
A proposal to use a building control technology under this Subpart shall include the following information:
a) A description of the site and physical site characteristics;
b) The current extent and modeled migration of contamination;
c) Geology, including soil types and parameters;
d) Results and locations of sampling events;
e) Scaled map of the area, including all buildings and man-made pathways;
f) A description of building characteristics and methods of construction, including a description of man-made pathways; and
g) Present and post-remediation uses of the land that are at issue due to the area of contamination, including human receptors at risk.
(Source: Added at 37 Ill. Reg. 7506, effective May 15, 2013) |