TITLE 35: ENVIRONMENTAL PROTECTION
SUBTITLE G: WASTE DISPOSAL
CHAPTER I: POLLUTION CONTROL BOARD
SUBCHAPTER f: RISK BASED CLEANUP OBJECTIVES
PART 742 TIERED APPROACH TO CORRECTIVE ACTION OBJECTIVES
SECTION 742.1205 BUILDING CONTROL TECHNOLOGY PROPOSALS


 

Section 742.1205  Building Control Technology Proposals

 

A proposal to use a building control technology under this Subpart shall include the following information:

 

a)         A description of the site and physical site characteristics;

 

b)         The current extent and modeled migration of contamination;

 

c)         Geology, including soil types and parameters;

 

d)         Results and locations of sampling events;

 

e)         Scaled map of the area, including all buildings and man-made pathways;

 

f)         A description of building characteristics and methods of construction, including a description of man-made pathways; and

 

g)         Present and post-remediation uses of the land that are at issue due to the area of contamination, including human receptors at risk.

 

(Source:  Added at 37 Ill. Reg. 7506, effective May 15, 2013)