TITLE 35: ENVIRONMENTAL PROTECTION
SUBTITLE G: WASTE DISPOSAL CHAPTER I: POLLUTION CONTROL BOARD SUBCHAPTER c: HAZARDOUS WASTE OPERATING REQUIREMENTS PART 725 INTERIM STATUS STANDARDS FOR OWNERS AND OPERATORS OF HAZARDOUS WASTE TREATMENT, STORAGE, AND DISPOSAL FACILITIES SECTION 725.1100 APPLICABILITY
Section 725.1100 Applicability
The requirements of this Subpart DD apply to owners or operators that store or treat hazardous waste in units designed and operated under Section 725.1101. The owner or operator is not subject to the definition of land disposal in 35 Ill. Adm. Code 728.102 provided that the following is true of the unit:
a) It is a completely enclosed, self-supporting structure that is designed and constructed of manmade materials of sufficient strength and thickness to support themselves, the waste contents, and any personnel and heavy equipment that operate within the unit, and to prevent failure due to any of the following causes:
1) Pressure gradients;
2) Settlement, compression, or uplift;
3) Physical contact with the hazardous wastes to which they are exposed;
4) Climatic conditions; or
5) The stresses of daily operation including the movement of heavy equipment within the unit and contact of such equipment with containment walls;
b) It has a primary barrier that is designed to be sufficiently durable to withstand the movement of personnel, wastes, and handling equipment within the unit;
c) If used to manage liquids, the unit has the following design features:
1) A primary barrier designed and constructed of materials to prevent migration of hazardous constituents into the barrier;
2) A liquid collection system designed and constructed of materials to minimize the accumulation of liquid on the primary barrier; and
3) A secondary containment system designed and constructed of materials to prevent migration of hazardous constituents into the barrier, with a leak detection and liquid collection system capable of detecting, collecting, and removing leaks of hazardous constituents at the earliest possible time, unless the unit has been granted a variance from the secondary containment system requirements under subsection 725.1101(b)(4);
d) It has controls sufficient to prevent fugitive dust emissions to meet the no visible emission standard in subsection 725.1101(c)(1)(D); and
e) It is designed and operated to ensure containment and prevent the tracking of materials from the unit by personnel or equipment.
(Source: Amended at 32 Ill. Reg. 12566, effective July 14, 2008) |