TITLE 35: ENVIRONMENTAL PROTECTION
SUBTITLE F: PUBLIC WATER SUPPLIES
CHAPTER I: POLLUTION CONTROL BOARD
PART 611 PRIMARY DRINKING WATER STANDARDS
SECTION 611.1057 ROUTINE MONITORING REQUIREMENTS FOR PWSS THAT SERVE MORE THAN 1,000 PEOPLE


 

Section 611.1057  Routine Monitoring Requirements for PWSs That Serve More Than 1,000 People

 

a)         General

 

1)         The provisions of this Section apply to public water systems serving more than 1,000 persons.

 

2)         Following any total coliform-positive sample taken under the provisions of this Section, the supplier must comply with the repeat monitoring requirements and E. coli analytical requirements in Section 611.1058.

 

3)         Once all monitoring required by this Section and Section 611.1058 for a calendar month has been completed, a supplier must determine whether any coliform treatment technique triggers specified in Section 611.1059 have been exceeded.  If any trigger has been exceeded, the supplier must complete assessments as required by Section 611.1059.

 

4)         Seasonal Systems

 

A)        A seasonal system supplier must demonstrate completion of an Agency-approved start-up procedure, which may include a requirement for start-up sampling prior to serving water to the public.

 

B)        The Agency may, by a SEP, exempt any seasonal system supplier from some or all of the requirements for seasonal system suppliers if the supplier's entire distribution system remains pressurized during the entire period that the supplier's system is not operating.

 

b)         Monitoring Frequency for Total Coliforms.  The monitoring frequency for total coliforms is based on the population served by the supplier's system, as follows:

 

Total Coliform Monitoring Frequency for Public Water Systems

Serving More Than 1,000 People

 

Population served

Minimum number of samples per month

1,001 to 2,500

2

2,501 to 3,300

3

3,301 to 4,100

4

4,101 to 4,900

5

4,901 to 5,800

6

5,801 to 6,700

7

6,701 to 7,600

8

7,601 to 8,500

9

8,501 to 12,900

10

12,901 to 17,200

15

17,201 to 21,500

20

21,501 to 25,000

25

25,001 to 33,000

30

33,001 to 41,000

40

41,001 to 50,000

50

50,001 to 59,000

60

59,001 to 70,000

70

70,001 to 83,000

80

83,001 to 96,000

90

96,001 to 130,000

100

130,001 to 220,000

120

220,001 to 320,000

150

320,001 to 450,000

180

450,001 to 600,000

210

600,001 to 780,000

240

780,001 to 970,000

270

970,001 to 1,230,000

300

1,230,001 to 1,520,000

330

1,520,001 to 1,850,000

360

1,850,001 to 2,270,000

390

2,270,001 to 3,020,000

420

3,020,001 to 3,960,000

450

3,960,001 or more

480

 

c)         Unfiltered Subpart B Systems.  A Subpart B system supplier that does not practice filtration in compliance with Subparts B, R, X, and Z must collect at least one total coliform sample near the first service connection each day that the turbidity level of the source water, measured as specified in Section 611.532(b), exceeds 1 NTU.  When one or more turbidity measurements in any day exceed 1 NTU, the supplier must collect this coliform sample within 24 hours after the first exceedance, unless the Agency determines that the supplier, for logistical reasons outside the supplier's control, cannot have the sample analyzed within 30 hours after collection, and the Agency identifies an alternative sample collection schedule.  Sample results from this coliform monitoring must be included in determining whether the coliform treatment technique trigger in Section 611.1059 has been exceeded.

 

d)         Reduced Monitoring.  A supplier may not reduce monitoring, except for a non-CWS supplier that uses only ground water (and not ground water under the direct influence of surface water) and which serves 1,000 or fewer people in some months and more than 1,000 persons in other months.  In months when more than 1,000 persons are served, the supplier must monitor at the frequency specified in subsection (a).  In months when the supplier serves 1,000 or fewer people, the Agency may, by a SEP, reduce the monitoring frequency, in writing, to a frequency allowed under Section 611.1054 for a similarly situated supplier that always serves 1,000 or fewer people, taking into account the provisions in Section 611.1054(e) through (g).

 

BOARD NOTE:  Derived from 40 CFR 141.857.

 

(Source:  Amended at 44 Ill. Reg. 6996, effective April 17, 2020)