TITLE 35: ENVIRONMENTAL PROTECTION
SUBTITLE B: AIR POLLUTION CHAPTER I: POLLUTION CONTROL BOARD SUBCHAPTER c: EMISSIONS STANDARDS AND LIMITATIONS FOR STATIONARY SOURCES PART 218 ORGANIC MATERIAL EMISSION STANDARDS AND LIMITATIONS FOR THE CHICAGO AREA SECTION 218.186 TEST METHODS
Section 218.186 Test Methods
The following test methods shall be used to demonstrate compliance with this Subpart:
a) Vapor pressures shall be determined by using the procedure specified in Section 218.110 of this Part.
b) Exhaust ventilation rates shall be determined by using the procedures specified in Section 218.105(f)(3) of this Part.
c) The performance of control devices shall be determined by using the procedures specified in Section 218.105(f) of this Part.
(Source: Amended at 17 Ill. Reg. 16636, effective September 27, 1993) |