TITLE 35: ENVIRONMENTAL PROTECTION
SUBTITLE B: AIR POLLUTION CHAPTER I: POLLUTION CONTROL BOARD SUBCHAPTER c: EMISSIONS STANDARDS AND LIMITATIONS FOR STATIONARY SOURCES PART 215 ORGANIC MATERIAL EMISSION STANDARDS AND LIMITATIONS SECTION 215.488 MONITORS FOR AIR POLLUTION CONTROL EQUIPMENT
Section 215.488 Monitors for Air Pollution Control Equipment
a) At a minimum, continuous monitors for the following parameters shall be installed on air pollution control equipment subject to this Subpart:
1) Destruction device combustion temperature;
2) Temperature rise across a catalytic afterburner bed;
3) Breakthrough of volatile organic material on a carbon adsorption unit;
4) Outlet gas temperature of a refrigerated condenser;
5) Temperature of a non-refrigerated condenser coolant supply system.
b) Each monitor shall be equipped with a recording device.
c) Each monitor shall be calibrated quarterly.
d) Each monitor shall operate at all times while the associated control equipment is operating.
(Source: Amended at 15 Ill. Reg. 8018, effective May 14, 1991) |